[vc_row row_type=”row” use_row_as_full_screen_section=”yes” type=”full_width” anchor=”portfolio” angled_section=”no” text_align=”left” background_image_as_pattern=”without_pattern” padding_top=”20″ padding_bottom=”10″ css_animation=””][vc_column width=”1/2″][vc_single_image image=”22199″ img_size=”500×350″ alignment=”center” qode_css_animation=””][/vc_column][vc_column width=”1/2″][vc_column_text css=”.vc_custom_1487361231488{padding-right: 20px !important;}”]

Shore Power Solutions

 

With our shore power converters, boaters can plug into our frequency converters to provide power to their ships at port.  This solution is ideal for international travel where the frequency of the power source available needs converted to correctly power the at-berth ship’s electronics.

 

PCTI’s solid state shore power converters cut fuel costs, reduce fuel emissions and air pollution from generators, and eliminate unnecessary noise.  They can be custom built to your specifications, up to 2MVA.

 

Our shore power converters are made for both indoor and outdoor applications.  The outdoor units are rugged enough to withstand a harsh marine environment, including tropical locations.  Our shore power supplies conform to at-berth regulations.
[/vc_column_text][vc_separator type=”normal” transparency=”0″ thickness=”2″ up=”20″][/vc_column][/vc_row][vc_row row_type=”row” use_row_as_full_screen_section=”yes” type=”full_width” anchor=”portfolio” angled_section=”no” text_align=”left” background_image_as_pattern=”without_pattern” padding_top=”20″ padding_bottom=”10″ css_animation=”” css=”.vc_custom_1487361060931{background-color: #ffffff !important;}”][vc_column width=”1/2″][vc_separator type=”normal” transparency=”0″ thickness=”2″ up=”30″][vc_column_text css=”.vc_custom_1487343677075{margin-left: 40px !important;}”]All PCTI frequency converters are equipped with a sophisticated control system utilizing digital signal processor (DSP) control based on IGBT PWM technology. This superior next-generation control allows us to provide a single control board solution for the frequency converter, thus increasing reliability by reducing control components.

 

Input power factor and harmonic distortion in the input current of a frequency converter can have detrimental effect on the utility grid supplying the converter, especially for higher power converters. All PCTI frequency converters for shore power application are designed to have very low input current distortion, THD < 5%, and almost unity power factor in the input.[/vc_column_text][/vc_column][vc_column width=”1/2″ css=”.vc_custom_1487343613478{margin-left: 40px !important;}”][vc_single_image image=”22200″ img_size=”500×350″ qode_css_animation=””][/vc_column][/vc_row][vc_row row_type=”row” use_row_as_full_screen_section=”no” type=”full_width” angled_section=”no” text_align=”left” background_image_as_pattern=”without_pattern” css_animation=””][vc_column][vc_separator type=”normal” transparency=”0″ thickness=”2″ up=”20″ down=”20″][vc_column_text]

Standard Specifications

[/vc_column_text][/vc_column][vc_column][vc_separator type=”normal” transparency=”0″ thickness=”2″ up=”20″ down=”20″][/vc_column][/vc_row][vc_row row_type=”row” use_row_as_full_screen_section=”no” type=”grid” angled_section=”no” text_align=”left” background_image_as_pattern=”without_pattern” padding_top=”25″ padding_bottom=”35″ css_animation=””][vc_column width=”1/2″][vc_column_text]
Input
Input service: Any 3 phase AC input
AC input frequency: 60Hz or 50Hz typical (contact factory for others)
Efficiency: Better than 85% at full load
Power factor: 0.95 to unity at full load and nominal input
Protection: Input circuit breaker
[/vc_column_text][vc_separator type=”normal” transparency=”0″][vc_column_text]
Output
Power range: 10KVA to 2000KVA (2MVA)
Output service: Any voltage
AC output frequency: 50Hz, 60Hz or others on request
Frequency regulation: + 0.05%
Regulation: 1% independent phase regulation for combined no load to full load at rated input voltage change control technology: Digitally synthesized pulse width modulation
Wave shape: Pure sinewave
Crest factor: 1.41 + 0.1%
Transient response: 50ms for a 90% load change on any phase or combination of phases
Current Limit: 110% of load
THD (Total Harmonic Distortion): less than 2% THD, 1% on any single frequency, less than 4% for non-linear loads
Power factor: 0.9 lead to 0.7 lag. Continuous zero lead to zero lag at full rated output without damage to the unit.
Overload capacity: 125% for 10 minutes, 150% for 2 minutes, 200% for 20 seconds (Optional) and 300% for 6 seconds (Optional)
[/vc_column_text][vc_separator type=”normal” transparency=”0″][vc_column_text]
Front Panel Devices
Power ON indicator
Run indicator
Undervoltage indicator
Overvoltage indicator
Voltage trim adjust from 90% to 10%
Start pushbutton
Stop/reset pushbutton
Fault indicator
Output voltmeter with 3 phase selector switch
Output ammeter with 3 phase selector switch
[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_column_text]
Protection
Input circuit breaker
Output contactor
Overvoltage
Undervoltage
Overcurrent/overload will withstand output short circuit cleared by internal circuitry
Output underfrequency
Overtemperature
Input to output transformer isolation
[/vc_column_text][vc_separator type=”normal” transparency=”0″][vc_column_text]
Features
Automatic line drop compensation
Automatic input line monitoring
Audible alarm
Emergency mushroom OFF switch
Electrical door interlock with bypass
Built in test and protection monitoring
MIL-STD-461 compliant for EMI/RFI
Standard conformance to IEC, NEMA, NEC, IEEE and other Mil-Spec
Indoor or outdoor enclosures
Computer interface/remote capability
Analog signals: 4-20mA, 0-5V, 0-10V or
Computer interface: Ethernet/IP, profinet, Modbus, CANbus, IEEE 488.2/GPIB, RS232, RS485
Remote functions: Start/stop, reset, current adjust, voltage adjust, voltage &amp; current reading, fault indication (UV, OV, OC, other)
[/vc_column_text][vc_separator type=”normal” transparency=”0″][vc_column_text]
Environmental
NEMA enclosure types: 1, 3R, 12, 4, 4X
Enclosure types: Mobile, towable, bridgemount or freestanding
Operating temperature: -5°C to 40°C
Storage temperature: -10°C to 65°C
Humidity: Up to 98% non-condensing at 40°C
[/vc_column_text][vc_separator type=”normal” transparency=”0″][vc_column_text]
Optional Features
Data & event logging
HMI touchscreen operation
Output circuit breaker
Frequency meter
Elapsed time meter
Mobile unit (pneumatic tires or casters depending on rating)
Dual output
Multiple selectable input voltages
Cable racks for input and/or output cables
[/vc_column_text][/vc_column][/vc_row]